Further, as an outstanding and comprehensive oil immersed distribution transformer solution provider, we respond to the oil immersed power transformer demanding requirements of our customers by developing and manufacturing both eco-friendly pole mounted distribution transformer and high-efficiency oil immersed power transformer.
Both oil immersed distribution transformer and pole mounted distribution transformer are designed for power centres,substations and network, also for pad mounted oil immersed power transformer, used in public distribution system, commercial building and industrial complexes

Standard Features

−− Product Range:15kVA-50MVA, up to 44kV

−− System voltage: max. 36 kVA 200 BIL

−− Coolers: corrugated wall or radiator

−Oil preservation: hermetically sealed or conservator/free breathing

−− Tap changer: off-circuit or on-load

−− Cooling medium: mineral oil, Midel

−− Steel type core clamping system

−− High voltage (HV) multilayer winding

−− Low voltage (LV) foil winding or layer winding

−− Winding materials aluminium or copper

−− High temperature class transformers

−− Low noise solution

−− Efficient transformers with reduced losses

−− Liquid-filled

−− Used in special conditions

−− Sophisticated facilities

−− Usage of wooden case

−− 3D package for drawings

−− Special test like Zero Sequence Impendence test

−− Cooling: ONAN, ONAN/ONAF, KFAF, KFW

Service condition

  1. a) Suitable for indoor or outdoor application

b)Air temperature: Maximum temperature: +40℃; Minimum temperature:-30℃

  1. c) Humidity: Monthly average humidity 95%; Daily average humidity 90% .
  2. d) Altitude above sea level: Maximum installation altitude: 2000m.

e)Max wind speed:35M/s

  1. f) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
  2. g) No frequent violent shake

Note: * Beyond those services condition should enquiry to manufacturer technical dept during order

inspection items

  • Voltage ratio. Polarity and phase relationship test on each tapping
  • Resistance of all windings
  • No-load current and no-load losses measurement
  • Load losses measurement at rated current and frequency
  • Impedance voltage measurement
  • Induced over-voltage and separate source voltage withstand tests
  • Impulse voltage withstand test.
  • Noise level test
  • Oil leakage test
  • Overload test at 150% rated current for one hour after temperature rise test and hot resistance measurement of (HV – LV)

11kV Series 3 Phase oil immersend transformer

kVA Voltage VECTOR GROUP LOSSES No-load Current Weight(kg) Overall dimension mm
H.V. kV L.V V No-load loss Load loss Oil weight Total weight L W H
20 6
6.3
10
10.5
11
13.2
380
400
415
433
Yyn0
Dyn11
Yzn11
90 530 2.3 55 230 720 440 855
30 100 600 2.1 75 305 750 500 990
50 130 870 2.0 80 405 800 480 1030
63 150 1040 1.9 95 455 830 615 1060
80 180 1250 1.9 105 510 840 580 1115
100 200 1500 1.8 120 530 890 645 1145
125 240 1800 1.7 130 670 910 600 1185
160 280 2200 1.6 140 810 910 700 1280
200 340 2600 1.5 160 890 1000 760 1240
250 400 3050 1.4 175 1020 1285 730 1290
315 480 3650 1.4 185 1170 1280 740 1385
400 570 4300 1.3 215 1410 1310 750 1432
500 680 5100 1.2 260 1645 1365 765 1510
630 810 6200 1.1 310 2070 1485 815 1615
800 980 7500 1.0 370 2445 1640 930 1590
1000 1150 10300 1.0 425 2800 1860 1120 1630
1250 1360 12000 0.9 480 3320 1860 1120 1830
1600 1640 14500 0.8 550 4175 1975 1175 1900

Note: *The above parameter is only subject to our standard design, special requirement can be customized

22kV Series

kVA Voltage VECTOR GROUP LOSSES No-load Current Weight(kg) Overall dimension mm
H.V. kV L.V V No-load loss Load loss Oil weight Total weight L W H
20 20
22
380
400
415
433
Yyn0
Dyn11
Yzn11
90 530 2.3 75 230 880 610 855
30 100 660 2.1 100 305 900 610 990
50 130 960 2.0 185 515 920 610 1150
63 150 1145 1.9 195 550 920 630 1180
80 180 1370 1.9 200 600 930 650 1200
100 200 1650 1.8 210 695 950 680 1250
125 240 1980 1.7 235 810 960 780 1270
160 280 2420 1.6 255 950 1160 710 1330
200 340 2860 1.5 280 1065 1190 730 1340
250 400 3350 1.4 300 1200 1280 820 1360
315 480 4010 1.4 320 1360 1380 910 1390
400 570 4730 1.3 370 1580 1430 950 1470
500 680 5660 1.2 400 1790 1520 1020 1510
630 810 6820 1.1 460 2100 1680 1150 1530
800 980 8250 1.0 495 2420 1810 1280 1580
1000 1150 11330 1.0 590 3080 1840 1290 1690
1250 1360 13220 0.9 630 3460 1850 1300 1730
1600 1640 15950 0.8 710 4015 1920 1350 1790

Note: *The above parameter is only subject to our standard design, special requirement can be customized

33kV Series

kVA Voltage VECTOR GROUP LOSSES No-load Current Weight(kg) Overall dimension mm
H.V. kV L.V V No-load loss Load loss Oil weight Total weight L W H
20 30
30.8
33
35
38.5
380
400
415
433
Yyn0
Dyn11
Yzn11
90 800 2.3 185 540 880 900 1200
30 100 1000 2.1 190 550 900 900 1200
50 210 1270 2.0 205 590 1000 950 1450
63 230 1500 1.9 210 620 1020 950 1500
80 250 1750 1.9 225 660 1050 970 1550
100 290 2120 1.8 240 790 1080 1000 1600
125 340 2500 1.7 270 950 1100 1030 1630
160 360 2970 1.6 285 1020 1130 1060 1630
200 430 3500 1.5 325 1170 1190 1060 1670
250 510 4160 1.4 340  